Page 108 - Eurotek Catalogue
P. 108







ELECTRICAL SPECIFICATION


Parameter Minimum Typical Maximum Units
Frequency range 8 - 19.7 Ghz
Isolation 18 - - dB
Insertion Loss - - 0.7 dB
VSWR input 1.5
VSWR output 1.5
Phase Unbalance +/-4 ˚
Amplitude Unbalance +/-0.2 dB
Forward Power 30 W cw
Reverse Power 2 W cw
Operating Temperature Range -55 - +85 ˚C
Impedance - 50 - Ω

























Strada Com. Savonesa n° 9
15057 Rivalta Scrivia (AL)
ITALY
Tel. +39 0131 860205 r.a.
Fax +39 0131 860993
e-mail: info@eurotek.eu
http://www.eurotek.eu







Rev.2017 16/11/2017